ID TECH Omni Bedienungsanleitung Seite 40

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 69
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 39
36
Select Code ID(s)
This command designates the bar code symbologies or magnetic stripe tracks
that will be accepted as valid.
SELECTION CODE: JC
UPC-A a
UPC-E b
EAN-8 c
EAN-13 d
Code 39 e
Interleaved 2 of 5 f
Industrial 2 of 5 g
Code 128 h
MSI/Plessey i
Codabar j
MSR Track 1 k
MSR Track 2 l
MSR Track 3 m
Telepen n
EXAMPLE:
To designate UPC-A, Code 39, Codabar, and MSR Track 1 as the only valid
sources of data, enter:
... JC<ENTER>a<ENTER>e<ENTER>j<ENTER>k<ENTER> ...
Set Length
Use this command to indicate a minimum and maximum number of
characters allowed for valid data. The first two digits set the minimum
length, and the second two digits set the maximum length. (This command is
optional.)
SELECTION CODE: JD
Two Digits for Minimum Length
Two Digits for Maximum Length
EXAMPLE:
To set the minimum number of characters at six, and the maximum at twelve,
enter:
... JD<ENTER>0<ENTER>6<ENTER>1<ENTER>2<ENTER> ...
Seitenansicht 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 68 69

Kommentare zu diesen Handbüchern

Keine Kommentare